GS 40.11 / GS 41.11

Accessories

TF06 Temperature sensor

Back part for surface wiring 200.004

Overview

  • Detection of air quality
    (CO2-concentration, rel. humidity, temperature)
  • CO2-sensor (Measuring range 390...5.000 ppm air pressure compensated)
  • CO2-value is atmospheric pressure compensated
  • Sensors for CO2-, temperature, humidity and atmospheric pressure measurement
  • Temperature sensor (Measuring range 0...+50 °C)
  • Humidity sensor (Measuring range 0...100 % rel. humidity)
  • Humidity comparator function
  • 5 binary and analogue inputs (e.g. for connecting an external temperature sensor)
  • Clearly structured ETS
  • Easy installation and mounting
  • Modern and planar design
  • Wall mounting [80 mm]
  • Party function
  • Extension of the value range of setpoints
  • Temperature control with up to 4 sensor values possible
  • Additional VAV controller
  • and much more
  • Additionally at GS 41.11 knx:
    manual adjustment of set-point temperature via touch panel (adjustment range ± 3°, increment 0,5°)

Information about CO2 and Covid-19

  • Every person is emitting CO2 and aerosols e.g. during breathing. Today aerosols are claimed to be one of the transmission ways of SARS-CoV-2. CO2-concentrations can be measured and the correlation between the CO2 and the aerosol concentration can be used for analytical investigations, which use the measured CO2-concentration to calculate a likely aerosol concentration. (TU Berlin)
  • A longer stay in small, bad or not ventilated room can increase the probability of a Covid-19 spread by aerosols even on bigger distances over 2 m. (RKI)
  • The use of our CO2-sensors and the resulting room ventilation helps minimizing the risk of infection e.g. in schools or offices, gyms, restaurants or other premises where several people stay together.

Order numbers

Logo Hugo MüllerGS 40.11 knx
CO2- air quality sensor & controller
GS 40.11 knx
CO2- air quality sensor & controller
GS 41.11 knx
CO2- air quality sensor & controller with manual set-point temperature adjustment ± 3°C
Logo Hugo Müller
Hugo Müller GmbH & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen
Tel: +49 (0) 7720 80 836 | Fax: +49 (0) 7720 80 83 88 | E-Mail: info@hugo-mueller.de | Internet: www.hugo-mueller.de
Logo Hugo Müller
Connect - KNX
Page 2 / 2

Air quality controllers

Air quality sensors & controllers
GS 40.11 / GS 41.11

Order information

EANArt. No.
GS 40.11 knx402270924300324300
GS 41.11 knx402270924301024301
GS 40.11 knx RAL9005 jet black402270924308924308
GS 41.11 knx RAL9005 jet black402270924309624309

Technical data

Supply voltage via KNX bus voltage
Bus current < 10 mA
Bus system KNX
Sensors CO2
temperature
relative humidity
atmospheric pressure
dew point
VAV ventilation control
Inputs 5 binary and analog inputs
I4 & I5: For external temperature sensor input (PT1000 or müller TF06 (10kΩ))
Manual operation
(only GS 41.10 knx)
manual adjustment of set-point temperature
(adjustment range ± 3 °, increment 0,5 °)
Measuring range CO2-concentration 390...5.000 ppm (air pressure compensated)
Measuring range temperature 0...+50 °C
Measuring range
relative humidity
0...100 %
Measuring range
atmospheric pressure
300...1.100 hPa
Permitted ambient temperature 0°...+50° C
Housing self-extinguishing thermoplastic
Dimensions 80,5 x 80,5 x 17 mm
Housing color studio white (similar to RAL 9016) or
jet black (similar to RAL 9005)
specific colors on request
Mounting wall mounting
(preferrably combined with flush-mounting box)
Type of connection push-in connector
Type of protection IP 20 (DIN EN 60529)
Class of protection III when installed according to regulations
Type of connection
external inputs
wire diameter max. 6 x 0,5 mm²
strip length 7 mm

Functions and data provided to KNX bus:

CO2 Value output
Control (step and PI control)
Relative humidity Value output
Control (step and PI control)
Comparator
Temperature Value output
Control heating (2-point- and PI control)
Control cooling (2-point- and PI control)
Alarms
Dewpoint Value output
Alarms
Air pressure Value output
VAV control Value output (0...100%)
and much more...
Rights to technical amendments reserved / Technische Änderungen vorbehalten
Droits de modifications techniques réservés / Suscettibile di errori e modifiche
Logo Hugo Müller
Hugo Müller GmbH & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen
Tel: +49 (0) 7720 80 836 | Fax: +49 (0) 7720 80 83 88 | E-Mail: info@hugo-mueller.de | Internet: www.hugo-mueller.de