Logo Hugo Müller
Connect - KNX
Page 1 / 2

Humidity controllers

Room temperature controllers and hygrostats
GS 30.11 knx / GS 31.11 knx

Accessories

TF06 Temperature sensor

Back part for surface wiring 200.004

Overview

  • Room temperature control
  • Sensors for temperature, humidity and atmospheric pressure measurement
  • Humidity sensor (Measuring range 0...100 % rel. humidity)
  • Humidity comparator function
  • Sensor for temperature measurement
  • Temperature sensor (Measuring range 0...+50 °C)
  • 5 binary and analogue inputs (e.g. for connecting an external temperature sensor)
  • Easy installation and mounting
  • Modern and planar design
  • Wall mounting [80 mm]
  • Party function
  • Extension of the value range of setpoints
  • Temperature control with up to 4 sensor values possible
  • Additional VAV controller
  • and much more
  • Additionally at GS 31.11 knx: manual adjustment of set-point temperature via touch panel (adjustment range ± 3 °, increment 0,5 °)

Order numbers

Logo Hugo MüllerGS 30.11 knx
Room temperature controller and hygrostat
GS 30.11 knx
Room temperature controller and hygrostat
GS 31.11 knx
Room temperature controller and hygrostat with manual set-point temperature adjustment ± 3°C
Logo Hugo Müller
Hugo Müller GmbH & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen
Tel: +49 (0) 7720 80 836 | Fax: +49 (0) 7720 80 83 88 | E-Mail: info@hugo-mueller.de | Internet: www.hugo-mueller.de
Logo Hugo Müller
Connect - KNX
Page 2 / 2

Humidity controllers

Room temperature controllers and hygrostats
GS 30.11 knx / GS 31.11 knx

Order information

EANArt. No.
GS 30.11 knx402270924302724302
GS 31.11 knx402270924303424303
GS 30.11 knx RAL9005 jet black402270924310224310
GS 31.11 knx RAL9005 jet black402270924311924311

Technical data

Supply voltage via KNX bus voltage
Bus current < 10 mA
Bus system KNX
Sensors temperature
relative humidity
atmospheric pressure
dew point
VAV ventilation control
Inputs 5 binary and analog inputs
I4 & I5: For external temperature sensor input (PT1000 or müller TF06 (10kΩ))
Manual operation
(only GS 31.11 knx)
manual adjustment of set-point temperature
(adjustment range ± 3 °, increment 0,5 °)
Measuring range temperature 0...+50 °C
Measuring range
relative humidity
0...100 %
Measuring range
atmospheric pressure
300...1.100 hPa
Permitted ambient temperature 0...+50 °C
Housing self-extinguishing thermoplastic
Dimensions 80,5 x 80,5 x 17 mm
Housing color studio white (similar to RAL 9016) or
jet black (similar to RAL 9005)
specific colors on request
Mounting wall mounting
(preferrably combined with flush-mounting box)
Type of connection push-in connector
Type of protection IP 20 (DIN EN 60529)
Class of protection III when installed according to regulations
Type of connection
external inputs
wire diameter max. 6 x 0,5 mm²
strip length 7 mm

Functions and data provided to KNX bus:

Relative humidity Value output
Control (step and PI control)
Comparator
Temperature Value output
Control heating (2-point- and PI control)
Control cooling (2-point- and PI control)
Alarms
Dewpoint Value output
Alarms
Air pressure Value output
VAV control Value output (0...100%)
and much more...
Rights to technical amendments reserved / Technische Änderungen vorbehalten
Droits de modifications techniques réservés / Suscettibile di errori e modifiche
Logo Hugo Müller
Hugo Müller GmbH & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen
Tel: +49 (0) 7720 80 836 | Fax: +49 (0) 7720 80 83 88 | E-Mail: info@hugo-mueller.de | Internet: www.hugo-mueller.de