Overview

  • Large format numerals 4.4 mm in height
  • Easy to connect – screw terminals accessible from rear
  • Attachments for other cutouts, see accessory
  • Ring seal for IP 54 – also seals front panel cutout
  • BG: quartz stabilized
  • BG: large voltage ranges

Highlights

  • with retaining clip
  • with universal connections
  • touch proof connections to VBG4
  • low-noise
  • BW: Alternating current
  • BG: Direct current quartz

Intended use

  • The device fits for the particular use of the following tasks: summed measuring of operating hours in control cabinets and plants, operating hours of pumps and machines.

Supply voltage versions

  • see technical data

Codice ordinativo

Logo Hugo MüllerBG 40.17
DC / Front 48x48mm
BG 40.17
DC / Front 48x48mm
BW 40.18
AC / Front 48x48mm
BG 40.27
DC / Front 55x55mm
BW 40.28
AC / Front 55x55mm
BG 40.37
DC / Front 72x72mm
BW 40.38
AC / Front 72x72mm
Logo Hugo Müller
Hugo Müller GmbH & Co KG | Karlstraße 90 | D-78054 VS-Schwenningen
Tel: +49 (0) 7720 80 836 | Fax: +49 (0) 7720 80 83 88 | E-Mail: info@hugo-mueller.de | Internet: www.hugo-mueller.de
Logo Hugo Müller
Prodotti
Pagina 2 / 2

Contatori tempo trascorso

müller BW 40 - BG 40

Order information

VoltageEANArt. No.
BG 40.1712-48 V DC402270920053220053
BW 40.18230 V 50 Hz402270920406620406
BW 40.1824 V 50 Hz402270920453020453
BG 40.2712-48 V DC402270920071620071
BW 40.28230 V 50 Hz402270920486820486
BG 40.3712-48 V DC402270921736321736
BW 40.38230 V 50 Hz402270920615220615

Other supply voltage versions on request

Technical data BW 40 alternating current

Voltage tolerance ±10%
Power consumption (real power) 0,15 W
Counter capacity 99.999 h.
Accuracy of reading 0,01 h.
Numeral height 4,4 mm
Numeral colour white, decimal figures red
Operation indicator fast-running wheel
Permitted ambient temperature –15…+55 °C
Housing self-extinguishing thermoplastic
Mounting Panel
Mounting aperture Square: 45 x 45 mm
Circle: Ø 50,5 mm
Type of connection Universal: Screw, soldered and
6.3 x 0.8 mm AMP plug-type connections
Type of protection Front IP 50 to DIN EN 60529
(with ring seal 101.003.004: IP 54)
Class of protection II when fitted in accordance with regulations

Technical data BG 40 direct current

Supply voltages
(please state when ordering)
12-48 V DC (Standard)
alt. 5-24 V DC
Voltage tolerance ±10%
Power consumption (real power) ca. 20 mW at 12 V DC
Counter capacity 999.999 h.
Accuracy of reading 0,1 h.
Numeral height 4,4 mm
Numeral colour white, decimal figures red
Operation indicator fast-running wheel
Permitted ambient temperature –10°…+50°C
Housing self-extinguishing thermoplastic
Mounting Panel
Mounting aperture Square: 45 x 45 mm
Circle: Ø 50,5 mm
Type of connection Universal: Screw, soldered and
6.3 x 0.8 mm AMP plug-type connections
Type of protection Front IP 50 to DIN EN 60529
(with ring seal 101.003.004: IP 54)
Class of protection III (bis 48 VDC) when fitted in accordance with regulations
Rights to technical amendments reserved / Technische Änderungen vorbehalten